Mechanical
Standard Hardware
Configuration:
Interface/Input Box, power supply, and choice of mouse scanner, available in
aperture sizes of 03, 05, 06, 10, 20 mils, or pen wand in 05, 06, and 10 mils.
(Choose visible for wand or infrared for mouse device.)
Plugs into PC
serial port
Optical Input Connector:
9-pin plastic squeeze-to-release male
Allows input from any existing or
potential future Hand Held Products interchangeable scanner (excluding laser)
I/O Connector:
6-pin modular
Allows for I/O communications with computer
Power Connector:
Power jack for powering input device and interface electronics
Uses
existing Hand Held Products QCAC charger
Environmental
Operating Temperature:
32 to 122° F (0 to 50° C)
Storage Temperature:
14 to 158° F (-20 to 70°C)
Relative Humidity:
5% to 95% Non-condensing
ESD Sensitivity:
Withstands 20 attempts to discharge 15Kv to the unit
Sealability:
Meets NEMA 1
Shock:
3 feet (91 cm) to concrete
Software
Verification Modes:
RL, RD, print contrast signal
ISO/IEC reflectance parameters
Bar/Space
dimensional measurement
Average bar growth/shrinkage
ISO/IEC
decodability
ISO/IEC 10-scan grade averaging
Wide-To-Narrow ratio
measurements
Scan profiles on CRT and printer output
Fixed message
length testing
"X" dimension calculation
Scan speed variation
indication
Variable or ISO/IEC symbol grade averaging
Storage of scan
results and scan profiles
Ability to add notations to scan file for later
retrieval
Programming Procedures:
Report generator allows choice of print format. Click directly on a
parameter to configure its setting
Verification Methods:
Parameters determined by the ISO/IEC print quality standard or traditional
pass/fail criteria
Result Indications:
Visual, using an efficient graphical display
Audible using the PC speaker
Display Organization:
Symbol Grade with Running Average
Scan Grade
Symbology and Symbol Data
Reflectance measurements, including RL, RD, Print Contrast, Rmin/Rmax, Minimum
Edge, Contrast, Modulation, and Defects
Format parameters, including Check
Digit and Message Length
Dimensional results, including Decodability,
Intercharacter gap, Wide-To-Narrow Ratio, and Average Bar Error
Additional
results and errors are available in a scrolling list
Symbologies Verified:
Code 39 (1 to 49 characters); Interleaved 2 of 5 (2 to 78 characters);
EAN/UPC (-A, -E, -8 and -13) includes magnification settings in a maximum of 16
steps
consisting of: 80, 85, 90, 95, 100, 105, 110, 115, 120, 125, 130, 140, 150, 160,
180 and 200%;
Codabar (1 to 61 characters); Code 128 (1 to 70 characters); Telepen
Applications:
UCC/EAN-128
Safety/Regulatory
FCC Class A, CE
IBM is a registered trademark of International Business Machines, Inc.
Windows is a registered trademark of Microsoft Corporation in the United States
and/or other countries.
Features
•
Custom
liquid crystal display (LCD)
• LCD
line scrolling
• LCD
image flip (left or right hand use)
•
Traditional test method
•
ANSI/CEN/ISO scan profile test method
•
Instant "On-Screen" ANSI/CEN/ISO grade
•
ANSI/CEN/ISO 10-scan grade averaging
•
Special reflectometer mode
•
Auto-discrimination of nine codes
• "X"
dimension determination
•
Detailed hard copy printout with optional printer
•
Automatic power off
•
Selectable beeper volume/pitch
•
Data buffer: 20 bar codes