MECHANICAL
Scanner
- Dimensions: 8.0 x 3.0 x 4.5" / 203 x 76 x 115 mm
- Weight: 13.5 oz / 383 g
Base Station (antenna down)
- Dimensions: 9.4 x 4.6 x 1.9" / 239 x 117 x 48 mm
- Weight: 12.6 oz / 358 g
Beeper/Speaker: 87 dBA for operator @ 50 cm (typical)
DECODING CAPABILITY (autodiscriminates among)
- Codabar
- Code 11
- Code 39
- Code 93
- Code 128
- Code 128 add-ons
- Code 128 ISBT
- EAN 128
- IATA
- Interleaved 2 of 5
- Italian Pharmacode 39
- Micro PDF
- MSI/Plessey
- P2 /P5 add-ons
- PDF-417
- Standard 2 of 5
- UPC/EAN/JAN
- RSS-14/Limited/Expanded (linear & stacked)
- Composites CC-A and CC-B (only RSS composites)
OPTICAL
Scanning Width: 2" wide at 1" from scanner; 6" wide at 7" from scanner
Minimum Resolution: 3 mil minimum element size
Skew (Yaw): ± 60°
Pitch: ± 65°
Roll: ± 40°
Depth of Field
Range Comparisons |
| LABEL DENSITY |
STANDARD RANGE
|
| 5 mil |
3 to 6" / 7.6 to 15.2 cm |
| 7.5 mil |
2 to 16" / 5.1 to 40.6 cm
|
| 10 mil |
1.5 to 22" / 3.8 to 55.9 cm |
| 13 mil |
1 to 30" / 2.5 to 76.2 cm |
| 20 mil |
1 to 42" / 2.5 to 106.7 cm
|
| 55 mil |
2 to 80" / 5.1 to 203.2 cm |
Minimum distance determined by symbol length and scan angle. Printing resolution, contrast, ambient light, temperature, and scan angle dependant.
ENVIRONMENTAL
Temperature Rating
- Storage (Scanner/Battery): -4° to 140° F / -20 to 60° C
- Storage (Base): -40° to 140° F / -40 to 60° C
- Operating: -4° to 122° F / -20 to 50° C
- Charging: 32° to 113° F / 0 to 45° C
Humidity: 5 to 95% NC
Shock: Withstands 50 drops from 6.5' / 2 m to concrete
Vibration: Meets MIL-STD-810E
Water & Particulate Sealing: IP65
ELECTRICAL
Base Station requires Datalogic Scanning approved power supply
Battery Charge Times
- In Base Station: Less than 4 hours
- In Optional Charger: Less than 4 hours
COMMUNICATIONS
Host Communications
- RS-232, Keyboard Wedge, USB, Wand Emulation, IBM 46XX, and USB (IBM SurePos)
- In addition to standard PC/AT/PS/2, the keyboard wedge interface supports the following: Wyse 55, 60, 120, 150, etc.; IBM 347X/3487/31XX; Digital VT220, 240, 320, 420, 510, 520; Sun 420, ITX, and Sparc 5/10.
SAFETY & REGULATORY
Electrical: Complies to UL; cUL; EN60950
Emissions: Complies to FCC; EN 55022; CISPR22
Radio: FCC Part 15C, R and TTE, and IC
Laser Classification: CDRH Class II,
(Caution: Laser Radiation - do not stare into beam);
IEC 60825 Class 2
Restriction of Hazardous Substances: Complies to EU RoHS
|